Active millimeter wave near field cylindrical scanning three-dimensional imaging system

WEN Xin1,2,3, HUANG Pei-kang4, NIAN Feng2,3, YANG Yu-jie3, FENG Ke-ming2,3   

  1. 1. Information Engineering School, Communication University of China, Beijing 10024, China;
    2. Science and Technology on Metrology and Calibration Laboratory, Beijing 100854, China;
    3. Beijing Institute of Radio Metrology and Measurement, Beijing 100854, China;
    4. National Electromagnetic Scattering Laboratory, Beijing 100854, China
  • Online:2014-06-16 Published:2010-01-03

Abstract:

In terms of the application of the active millimeter wave near field cylindrical scanning three-dimensional imaging system in human security, the reconstruction algorithm of the system is researched. The bandwidth of the signal, the sampling criteria and the evaluation method of the resolution in the three-dimensional rectangular coordinate of the system are presented. The high quality echo data is obtained in the anechoic chamber to verify the validity of the imaging system in theory. Based on the experiments, the high speed active millimeter wave near field cylinder scanning three-dimensional imaging human security system is set up to verify the application feasibility and the effectiveness of detection capability of the imaging system in the field of human security.