Abstract:
The form of wide-band group delay is analyzed and Ka-band interferometry is taken as the background. For the problem of nonlinear distortion of channel group delay, a calibration method based on cross-correlation of phase calibration (PCAL) signals is proposed. Comb-spectrum and linear phase are key characteristics of PCAL, according to this, the phase-frequency characteristic curve of crosscorrelation is obtained by extracting PCAL’s phase, and then the channel group delay is calculated. For parabolic group delay, third-order nonlinear fitting is used to replace the traditional first-order linear fitting. Simulation results show that when the signal-to-noise ratio is -10 dB, the third-order fitting has a higher agreement with the original phase-frequency characteristic curve, the standard deviation accounts for 1/4 of the first-order fitting and the group delay result is closer to the true value. The validity of the algorithm is proved.
ZHAO Qiang, HOU Xiaomin, JIAO Yiwen. Calibration of channel group delay nonlinearity error applied in wide-band interferometry[J]. Systems Engineering and Electronics, doi: 10.3969/j.issn.1001-506X.2017.06.06.
0 / / Recommend
Add to citation manager EndNote|Reference Manager|ProCite|BibTeX|RefWorks
URL: https://www.sys-ele.com/EN/10.3969/j.issn.1001-506X.2017.06.06
https://www.sys-ele.com/EN/Y2017/V39/I6/1221